ST-3/VLW Adapter | XT Series Accessory
The ST-3/VLW adapter with the SensorLink® Volt Litewire enable testing of overhead installation with the ST-3/XT3
The ST-3/VLW Adapter enable the usage of the SensorLink® Volt Litewire adapter to perform a Primary/Secondary Test using the ST-3/XT3 with overhead installations. The accessory is electronically compensated and automatically detected when plugged in. The Primary/Secondary Test is automatically adjusted by the Probewell Connect 2.0 application to reflect the functionality.
- Electronically compensated
- Automatically detected by the ST-3/XT3
SKU: 9030-3425
The ST-3/VLW Adapter enable the usage of the SensorLink® Volt Litewire adapter to perform a Primary/Secondary Test using the ST-3/XT3 with overhead installations. The accessory is electronically compensated and automatically detected when plugged in. The Primary/Secondary Test is automatically adjusted by the Probewell Connect 2.0 application to reflect the functionality.
- Electronically compensated
- Automatically detected by the ST-3/XT3
SKU: 9030-3425
ST-3/VLW Adapter | Installation
The ST-3/VLW adapter lets you connect the SensorLink® Volt Litewire accessory to the Probewell ST-3/XT3 site tester when testing overhead installations. (This accessory only lets you test one phase at a time.)
The ST-3/XT3 Transformer-Rated Site Tester verifies the three phases simultaneously when used with the ST-3/FLEX-CT2500 accessory.
How to run the test using the Probewell Connect 2.0 application.
While testing a transformer, the Probewell Connect 2.0 app will prompt the user to manually switch the amp probe to the next phase until the 3 phases of the CT meter have been tested. (A followed by B then C).
- Connect the SensorLink® Volt Litewire BNC cable to the BNC jack on the VLW adapter
- Connect the 12-pin connector of the VLW at the other end to the ST-3/XT3’s PT front port
- When powered on, the unit will automatically detect the ST-3/VLW adapter. The Probewell Connect 2.0 app can now proceed with the test (refer to the Probewell Connect 2.0 User Guide for details).
The ST-3/VLW adapter lets you connect the SensorLink® Volt Litewire accessory to the Probewell ST-3/XT3 site tester when testing overhead installations. (This accessory only lets you test one phase at a time.)
The ST-3/XT3 Transformer-Rated Site Tester verifies the three phases simultaneously when used with the ST-3/FLEX-CT2500 accessory.
How to run the test using the Probewell Connect 2.0 application.
While testing a transformer, the Probewell Connect 2.0 app will prompt the user to manually switch the amp probe to the next phase until the 3 phases of the CT meter have been tested. (A followed by B then C).
- Connect the SensorLink® Volt Litewire BNC cable to the BNC jack on the VLW adapter
- Connect the 12-pin connector of the VLW at the other end to the ST-3/XT3‘s PT front port
- When powered on, the unit will automatically detect the ST-3/VLW adapter. The Probewell Connect 2.0 app can now proceed with the test (refer to the Probewell Connect 2.0 User Guide for details).
Probewell Support Portal
Help yourself to our product documentation to rapidly find answers to your questions and troubleshoot your product.
Trade-in & Trade-Up
If you own an older-generation Probewell product, you are automatically eligible for our trade-in program.
Trade in your old meter tester and get up to 1,000 USD* off the purchase of any of our newer models.
*US customers only. If you are a customer from outside the United States, please contact Probewell.
Trade-in and Trade-Up
If you own an older-generation Probewell product, you are automatically eligible for our trade-in program.
Trade in your old meter tester and get up to 1,000 USD* off the purchase of any of our newer models.
*US customers only. If you are a customer from outside the United States, please contact Probewell.